About 50 results
Open links in new tab
  1. Romex | Information by Electrical Professionals for Electrical ...

    Sep 6, 2013 · In the code book it says that you can install Romex if permitted as a Type 3, 4 or 5 building, but if it is permitted as a type 1 building you can not install Romex. Although IF the building …

  2. Romex wiring in garage | Information by Electrical Professionals for ...

    May 8, 2015 · I'm buying a house and there is romex wiring run through the garage. The installation was approved by the township in 1987 when it was installed. Current standards requireany type of non …

  3. That old Romex question again. | Information by Electrical ...

    Mar 12, 2022 · Hello all. Got a question. I am wiring an office building for a family member's used car lot. The building was a two story split level residential home with a basement that is being converted to …

  4. Romex in conduit attached to an enclosure (indoors), fastening ...

    Dec 17, 2024 · When using conduit to protect Romex before it enters an enclosure - for example, coming up out of the crawlspace, up an un-finished wall to a disconnect - what fastening …

  5. Garage romex protection | Information by Electrical Professionals for ...

    Mar 29, 2010 · Where in the code is it required, (or not) the need to protect NM cable run in a garage, horizontally through bored holes in stud runs that are exposed (not covered with drywall? Items can …

  6. What year were you required to use 14/2 12/2 Romex WITH A GROUND.

    Apr 23, 2024 · All 12/2 or 14/2 cloth Romex and range cable was cloth covered 3 wire. 10-2 cloth Romex to water heater. 60 amp panel was grounded to water line nearby. I first noticed grounded …

  7. Romex and SER ampacities. | Information by Electrical Professionals for ...

    May 12, 2021 · As far as SER it seems that #4 is the best choice for a 60 amp feeder cable, (if we can use 75 degrees) since it is usually readily available, and #4 romex would be severe overkill. Talking …

  8. Installing romex in EMT conduit | Information by Electrical ...

    Sep 20, 2022 · I also recently passed romex through a double gang metallic box without breaking wires out of jacket, straight in left to exit rear. Code requires equipment to be bonded if likely to be …

  9. Romex Connectors installed from the inside of the box

    Jul 23, 2007 · Does anyone know of a romex connector that can be installed from the inside of an EXISTING junction box. I can't access the outside of the box without opening up the drywall, and the …

  10. Types of conductors inside Romex cable | Information by Electrical ...

    Jul 16, 2014 · Are the individual conductors inside a piece of 14/2 or 12/2 Romex cable THHN or THWN type? What about those inside of an 8-3 or 6-3 Romex?